Low density polyurethane insulation Polyurethane Spray S-OC-010

Low-density polyurethane systems are suitable for improving the thermoacoustic insulation of buildings. There are numerous advantages in their use, such as the elimination of thermal bridges, good adhesion to the substrate and ease of mobility, as we don’t have to transport or store bulky products as in the case of other materials for insulation.

Synthesia Technology's Polyurethane Spray S-OC-010 is a polyurethane system designed to improve thermocoustic insulation against airborne noise in building enclosures, both in partitions between neighbours and exterior façades.

Low density polyurethane insulation Polyurethane Spray S-OC-010

 

The polyurethane system Polyurethane Spray S-OC-010

Polyuretan Spray S-OC-010 is an acoustic polyurethane system in two components: polyol and isocyanate. The system is applied by "in situ" sprayed polyurethane foam, obtaining low density open cell foam (9-11 g/l) with good acoustic absorption properties. The Polyuretan Spray S-OC-010 system does not contain foaming agents that damage the ozone layer.

Characteristics

Free Density

10±1 g/l

Apparent Core Density

10±1 kg/m3

Closed Cell Content

<20%

Reaction to fire (60 mm)

F

Water absorption (Wp)

≤3’5 kg/m2

Water vapour resistance factor (μ)

≥5

Acoustic absorption

0,5

Airflow resistivity r

5-6 kPa s/m2

Dynamic stiffness s'

4,83 MN/m3

Thermal resistance and termal conductivity

35-300 mm: 0,036 W/mK

 

 

Application of the Polyuretan Spray S-OC-010 system

The Polyuretan Spray S-OC-010 system is applied by spraying with high pressure equipment, equipped with heating, with a mixing ratio of 1:1 in volume. Its main application is the improvement of thermal-acoustic insulation to airborne noise in building enclosures, both in partitions between neighbours and exterior facades.

One aspect to be taken into account when applying is to avoid an excessive overlapping of the successive applications that are necessary to cover the work surface. In this way, irregularities in the sprayed surface are reduced and the applied thickness is better controlled.

The recommended initial setpoint temperature of the hoses and preheaters is 50-60ºC. The recommended initial setpoint pressure is 800-1200 psi. The recommended minimum temperature of the substrate during the spray application is 5ºC and the temperature of the components is 20-30ºC.

Low density polyurethane insulation Polyurethane Spray S-OC-010

 

Fire response test Poliuretan Spray S-OC-010

Features

Euroclass

Conditions

Fire response in end-use application

B s1 d0

Laminated gypsum board  15 mm.

Air chamber 15-20 mm.

 

Sound absorption test Poliuretan Spray S-OC-010

Sound absorption of Polyuretan Spray S-OC-010 has been determined at different frequencies in reverberant chamber according to the UNE-EN 20354:1993 standard. The results obtained, as well as the sound absorption values of closed-cell polyurethane foam for thermal insulation such as Polyuretan S Spray, are shown in the following table. 

Frequency (Hz)

Sound absorption coefficient
UNE-EN 20354:1993

Poliuretan Spray S-OC-010

Poliuretan Spray

125

0,20

0,12

250

0,40

0,18

500

0,80

0,27

1.000

0,60

0,19

2.000

0,40

0,62

4.000

0,50

0,22

NRC (noise transmission reduction coefficient)

0,50

0,32

 

Do you want to know the most efficient thermoacoustic insulation solutions? Download the document below or contact us to receive more information about Synthesia Technology's polyurethane systems for thermoacoustic insulation: 

Guide of polyurethane solutions for thermal and acoustic insluation

 

Related posts

Comments

FEATURED POST


Fire response of polyurethane: false myths

Polyurethane systems surround our daily lives, however, we still hear some voices that call into question the response of polyurethane in case of fire. 

Read more

MOST VIEWED ARTICLES

SUBSCRIBE TO OUR BLOG

Nuevo llamado a la acción
CONTACTA CON SYNTHESIA INTERNACIONAL